Commission the cell
Bring every safety rule together: two-channel devices, both stop categories, muting and contactor checks.
Write the whole cell: a two-channel E-stop (category 0), a two-channel gate (category 1), a muted light curtain (category 1), discrepancy and contactor checks, and a deliberate reset and start.
Training only. This is not a certified safety system. On a real machine these rules run in a safety relay or a safety PLC, designed and validated to ISO 13849-1 or IEC 62061.
Pro missionRun, and let a carton through
Test 1 of 6StartInputOFFResetBlue Reset button, outside the fenceOFFEStopAInputONK1OutputON- Level
- Expert
- Time
- About 75 min
- Reward
- +900 XP
- Rig
- 3D robot safety cell
- Siemens editors
- Ladder (LAD), SCL
- Rockwell editors
- Ladder, Structured Text
- Beckhoff editors
- Structured Text
- Course stage
- 35. Safety capstone: commission the cell
What the tests check
- E-stop or any fault: power off at once (category 0).
- Gate or an unmuted curtain break: brake, then power off at Standstill or after 1 s (category 1).
- Cartons pass the curtain muted; people do not.
- Channel and contactor faults , light FaultLamp and block the reset.
- Nothing restarts without a fresh Reset and then a fresh Start.
- Try it Use the buttons below the model and watch the rig respond.
- Test solution Every check runs on your code in one press.
- Replay If one fails, step through it one scan at a time to see why.
Where you’d see this on site
Commissioning a cell means proving every safety function, one device and one fault at a time, and writing the result down.
Each device on its own is simple. Together, one rule can quietly undo another: a reset that clears a fault, or muting that outlives its carton. Only a full test of every case shows the cell is right.
A robot stacks cartons inside a fence. A gate lets a fitter in, a light curtain lets the cartons in, and an emergency stop sits outside. Two contactors in a row cut the robot's power, so one that sticks cannot keep it running.
- InfeedCartons through the curtain
- PickRobot takes the carton
- GuardStop, reset, restartYou are here
- PalletSix cartons, then change
On a real site: places, parts and safety
- Robot palletising and packing cells
- Machine tending: robots loading presses and machine tools
- Any guarded machine with a door, a curtain or an E-stop
Training only: this rig is not a certified safety system. Real safety functions run in safety relays or a safety PLC, designed and validated to ISO 13849-1 or IEC 62061.
IEC 60204-1 sets out stop categories 0, 1 and 2 and how an emergency stop must behave. Which category a machine uses comes from its risk assessment.
The sizes, timings and cutaways are teaching choices, not a drawing of any one real installation.
Next in the course
- Grey is normalSave colour for the things an operator must act on.Applied · 20 min · +300 XP
- Read it at a glanceAnswer 'is it all right?' in one second, in plain words.Applied · 25 min · +300 XP
- Alarms in priority orderNew alarms flash and sound until acknowledged; the urgent one comes first.Advanced · 30 min · +350 XP
- Ask before you can't undoConfirm only what can't be taken back, and say what will happen.Advanced · 30 min · +350 XP