Pack six, then pause
Count six bottles, stop for the pusher, then go again.
Count each bottle once as it arrives at BottlePresent. At the sixth, stop ConveyorOn and light PackReady for 2 seconds while the pusher takes the pack. Then run the belt again and count the next six from zero. Run OFF stops the belt but keeps the count.
Every Pro challenge is free for a day when it comes round as the daily challenge.
Pro challengeSix bottles make a pack
Test 1 of 4RunInputONBottlePresentInputOFFConveyorOnBelt commandONPackReadyPack completeOFF- Level
- Medium · 20 points
- Kind
- Code it
- Time
- About 18 min
- Pass rate
- New
- Machine
- 3D filling line
- Siemens
- LAD and SCL
- Rockwell
- Ladder and Structured Text
- Beckhoff
- Structured Text
What the checks test
- Each bottle counts once, however long it sits on the .
- The sixth bottle stops the belt and lights PackReady for 2 s.
- After the pause the belt runs and the next pack counts from zero.
- Run OFF stops the belt; the bottles counted so far still count.
The checks run 4 tests on the machine, scan by scan: Six bottles make a pack; A bottle sitting on the sensor counts once; The next pack starts from zero; Run OFF stops the belt and keeps the count.
Where you’d find this
A bottling line groups bottles into packs of six. The belt pauses while a pusher moves each pack onto the shrink wrapper.
Counting one bottle twice, or missing one, sends short packs to the customer and jams the wrapper.
How it should behave
- Count
- One count per bottle arriving at the sensor.
- Pack
- At six: belt stops, PackReady for 2 s.
- Run
- Run OFF stops the belt and keeps the count.
Press Run and watch the bottles. After the sixth the belt pauses for 2 s, then the next pack starts.
More challenges
- The output that won’t listenStart does nothing. Jog works. Find out why.Easy · Find the fault
- The timer that never finishesA three-second start delay that only works if you hold the button.Easy · Find the fault
- Overflows by a dropFill to 80%. At exactly 80%, the valve stays open.Easy · Find the fault
- The alarm you can’t clearAfter the storm, Reset does nothing. During it, Reset worked.Medium · Find the fault